- Overview of the Optical and Control Setup of the pulsed optical synchronization system at ELBE
- Results of performance measurements of the system done in 2019
- Actual Goals and Challenges
Summary
At ELBE a pulsed optical synchronization system is installed in order to provide reference signals to machine subsystems as well as to table top laser systems with a stability on the femtosecond level. In the recent years the system has been updated and is now using polarization maintaining fibers. The updated system is in operation since spring 2018.
The poster will show an overview of the setup and provide results of performance measurements which were recently done.
Primary author
Andreas Schwarz
(Helmholtz-Zentrum Dresden-Rossendorf, radiation source ELBE)
Co-author
Dr
Michael Kuntzsch
(HZDR)