Dr
Xiaoye He
(National Synchrotron Radiation Laboratory, University of Science and Technology of China)
16/09/2010, 15:40
status reports (no oral presentation, only for poster)
The light source at National Synchrotron Radiation Laboratory(NSRL), University of Science and Technology of China (USTC), Hefei, Anhui province, China, is called Hefei Light Source which is called HLS for short (which is different from the meaning of Hydrostatic Levelling System here). Hefei Light Source was initially built from 1984 to 1992. Now, as plan from 2010 to 2012, Hefei Light...
Mr
Mark Jones
(CERN)
16/09/2010, 15:40
poster
Over a long period of time the least squares compensation program at CERN, LGC, has been gradually re-written in C++. Part of the program has been integrated into a software library, which is also used in a number of other programs, with the functionality specific to LGC built on top. The geodetic transformations used within the program have been updated and a sparse matrix representation...
Catherine Le Cocq
(SLAC)
16/09/2010, 15:40
poster
The integration of laser scans into a Geographic Information System (GIS) is presented. Examples include detailed scans of the Beam Transport Hall (BTH) in SLAC's Linac Coherent Light Source (LCLS). These scans were made at various density levels and portions were subsequently added to an evolving GIS for the Metrology Department. This poster highlights various results of this integration and...
Mika Masuzawa
(KEK)
16/09/2010, 15:40
poster
Results on performance test of laser trackers of FARO are presented. Test was performed on the following items. (1) Drift of output after power on, (2) long term variation of output, (3) reproducibility of point measurements, and (4) comparison between measurement with a laser tracker and the one with a stretched wire.
Jaromir Penicka
(Argonne National Laboratory)
16/09/2010, 15:40
poster
One of the many responsibilities of the Survey and Alignment team at the Advanced Photon Source (APS) is the periodic monitoring of the positional stability of the Radiation Safety System (RSS). The RSS for all operational experiment x-ray beamlines consist of approximately one thousand RSS components. Access to these components is limited to a brief maintenance period, and the use of...
Mr
Georg Gassner
(SLAC National Accelerator Laboratory)
16/09/2010, 15:40
poster
This poster presents the major survey and alignment activities at the SLAC National Accelerator Laboratory since 2008. The major project during the last two years has been the construction of the Linac Coherent Light Source (LCLS) with the development of beam lines still ongoing. Besides the LCLS project a variety of smaller projects are under way. This poster will give a brief overview of the...
Dr
David Sanderson
(Michigan State University)
16/09/2010, 15:40
status reports (no oral presentation, only for poster)
Michigan State University is presently installing a reaccelerator project at the National Superconducting Cyclotron Laboratory(NSCL) and planning the Facility for Rare Isotope Beams (FRIB). The status of alignment activities for the two projects will be shown.
Richard Ford
(FNAL)
16/09/2010, 15:40
status reports (no oral presentation, only for poster)
Survey and alignment activities at Fermilab since 2008 will be presented with an eye towards future projects and challenges as we approach the post-Tevatron era.
Mr
Alexis LEFEVRE
(GANIL - CEA/DSM-CNRS/IN2P3)
16/09/2010, 15:40
Survey & alignment of machine components and experiments
The SPIRAL2 project located at the Grand Accélérateur National d’Ions Lourds (GANIL facility - Caen, France) has been studied since the beginning of 2001, and is now under construction. This project aims at delivering rare (radioactive) isotope beams with intensities not yet available with presently running machines. An important aspect of this project is that it is foreseen to deliver up to...
Mr
Martin Noak
(DESY), Mr
Wolf Benecke
(DESY)
16/09/2010, 15:40
Dr
Tatsuya Kume
(KEK)
16/09/2010, 15:40
poster
We adopted straightness measurement using a level for evaluating vertical aligning straightness of the 600-m-long KEK electron/positron linac. It measures tangential angles of the straightness and obtains the straightness by integrating the measured angles without affected by any substantial straightness references.
Here, straight bars with length of from 1640 mm to 2306 mm were put on...
Mr
Davide Bianculli
(FONDAZIONE CNAO (ITALY))
16/09/2010, 15:40
status reports (no oral presentation, only for poster)
The Centro Nazionale Adroterapia Oncologica (CNAO) is the first medical accelerator facility for hadrontherapy with C6+ and protons in Italy. Two ECR ion sources produce a beam injected into a LINAC and accelerated at 7 MeV. A 78m circumference synchrotron stores and accelerates the beam up to 400 MeV/u. Each one of the three treatment rooms receives the beam extracted by the synchrotron; the...
Yasunobu Ohsawa
(KEK)
16/09/2010, 15:40
poster
A new set of monuments was installed for the SuperKEKB project.
SuperKEKB is a next-generation B-factory which uses the same tunnel as
KEKB. Many magnets will be replaced or relocated for SuperKEKB in order
to realize collisions with extremely small beams. Placing survey
monuments in the accelerator tunnel, which was built three decades ago,
was not an easy task for many reasons, as will...
Mr
Fabien Rey
(CELLS)
16/09/2010, 15:40
poster
ALBA, a third generation synchrotron light facility built in Barcelona is now almost ready for commissioning. Mechanical installation is now completed and the 100 MeV LINAC as well as the 3 GeV booster injector have already been commissioned.
The survey and alignment strategy presented during previous workshops has been implemented and allowed us to fulfill all physicist requirements...
Mr
Patrick Bestmann
(CERN)
16/09/2010, 15:40
instrumentation, software and methods
For the Compact Linear Collider (CLIC) project an active pre-alignment system is planned to be used with thousands of wire position sensors (WPS). The capacitive WPS technology used at CERN is rather expensive and limited to the use of conductive reference wires. Alternative sensor and wire solutions are studied.
Open Source Instruments Inc is developing a CCD camera based WPS. This sensor...