Topic: LUXE simulation and analysis TF
Meeting ID: 916 7025 7822
Password: 434044
Time: This is a recurring meeting Meet anytime
Join from PC, Mac, Linux, iOS or Android: https://weizmann.zoom.us/j/91670257822?pwd=L01uZHJMTmtmNkdpUklOTnlMU1M5QT09
Or Telephone:
Dial(for higher quality, dial a number based on your current location):
US: +1 206 337 9723 or +1 470 250 9358
United Kingdom: +44 131 460 1196 or +44 203 481 5237
Israel: +972 3 978 6688
Meeting ID: 916 7025 7822
Password: 434044
International numbers available: https://weizmann.zoom.us/u/aQxpHqFgj
Or an H.323/SIP room system:
H.323:
162.255.37.11 (US West)
162.255.36.11 (US East)
115.114.131.7 (India Mumbai)
115.114.115.7 (India Hyderabad)
213.19.144.110 (Amsterdam Netherlands)
213.244.140.110 (Germany)
103.122.166.55 (Australia)
149.137.40.110 (Singapore)
64.211.144.160 (Brazil)
69.174.57.160 (Canada)
207.226.132.110 (Japan)
Meeting ID: 916 7025 7822
Password: 434044
SIP: 91670257822@zoomcrc.com
Password: 434044
Or Skype for Business (Lync):
https://weizmann.zoom.us/skype/91670257822
Offline discussions:
- Latest design of the IP box (Asaf, Ishay, Matt,…) —> following last week’s presentation (merging of the 2 lines, dump, etc)
- beam focusing at the IP
- ICS box design (Stuart+Stewart, Louis, Matt, Daniel,…) —> space?, what are the requirements on the focusing?, who designs it?
- adding shielding on the top of the electrons tracker (Oz)
Louis:
- prefer to have one line (input and return)
- doable, need special custom made optics
- bellows are big enough to avoid
- simulate the mirrors inside the IP box —> Sasha is implementing it now
- vacuum: elements in the box cannot cope with the XFEL level (1e-8 mbar). use differential pumps between the machine and our setup (1e-4 mbar is OK but we may need better). We have 1e-8 in GEANT4 now and Sasha will check 1e-4 in fast simulation when possible.
- laser-beam dump can be put outside the chamber ~15 cm in another beam.
- ICS box maybe we have 20+15 cm
Sasha:
- finishing today preliminary implementation of the elements inside the IP box
- launch by the end of this week.
- will check with fast sim with a vacuum of 1e-4
- need more signal points —> Arka will tell Sasha
Marco:
- calibrate the profiler with a dedicated run with photons —> will get that from the Bremss runs.
- Sasha: will also run this with fast sim for better stats
John:
- photons distribution is higher than in the CDR, probably due to the proximity to the dump
- maybe need to move the screen a few mm’s away from the beam
- design of Cherenkov doesn’t have straws in the path of the beam!
- but here, we have straws in the path of the beam Cherenkov sees too few beam electrons ()
Maryna:
- dose from depositions GeV—>Joule—>use specific mass—>Gy
- tracker at ~1e-6 Gy
Shan:
- too large background coming from the back?
- need to look at vertices etc to conclude but it is not good to compare fast sim and full sim since all particles arriving to the dump are killed and so there’s no bkg from the beam dump.