12–13 Nov 2018
Helmholtz-Zentrum Geesthacht <br> outstation at DESY
Europe/Berlin timezone

Phase-contrast X-ray microscopy and tomography on EMBL beamline P14 at PETRA III

12 Nov 2018, 14:50
25m
Bldg 66, Seminar room (Helmholtz-Zentrum Geesthacht <br> outstation at DESY)

Bldg 66, Seminar room

Helmholtz-Zentrum Geesthacht <br> outstation at DESY

Notkestr. 85, D-22607 Hamburg, Germany
Oral presentation Session 2

Speaker

Mr Maxim Polikarpov (EMBL)

Description

EMBL Hamburg operates the P14 beamline at the high-brilliance PETRA III storage ring at DESY. Delivering hard X-rays (6 – 30 keV), P14 is very versatile: shape, size and intensity of the X-ray beam are easily tunable by using both reflective and refractive optical elements. Sample stage and detecting systems are state-of-the-art including a high-precision vertical goniometer (developed in collaboration with EMBL Grenoble and ARINAX, a robotized sample changer (developed in-house) and a DECTRIS (Baden, Switzerland) EIGER 16M detector. These features enable crystallography of large macromolecular complexes, serial crystallography, time-resolved and in-situ diffraction data collection. Exploiting the flexibility of the beamline optics, we are investigating new methods and techniques to look into samples of interest via full-field phase-contrast X-ray imaging and microscopy. Unlike conventional absorption X-ray imaging, phase contrast makes interfaces and density gradients clearly visible in a biological sample. To achieve higher resolution and to see fine structure, we also implement X-ray refractive lenses as an objective in the microscopy mode. This approach allows us to magnify details of the sample up to 15 times prior to the optical detection of X-rays that carry the phase-contrast information from the interaction with sample. With the current setup, a sub-100nm resolution can be achieved and it is possible to visualize crystal boundaries and their local deformations in situ. High-precision rotation of the sample stage at P14 also allows to perform X-ray tomography. Due to the use of high-energy X-rays for the imaging process, materials and tissues with thicknesses in the mm-range can be penetrated. The latter also allows P14 to look forward for time-resolved experimental applications with other biological objects.

Primary author

Co-authors

Mr Anatoly Snigirev (Immanuel Kant Baltic Federal University) Gleb Bourenkov (EMBL Hamburg) Mr Thomas Schneider (EMBL Hamburg)

Presentation materials

There are no materials yet.