Conveners
Session 3
- Marc Weber (KIT)
Dr
Daniela Dorner
(Universität Würzburg)
03/06/2014, 09:20
Apart from long-term monitoring of bright TeV blazars, the major goal of the First G-APD Cherenkov Telescope (FACT) was the proof of principle for silicon based photosensors (Geier-mode Avalanche Photodiodes aka SiPM) in Cherenkov Astronomy. In 2.5 years of operation so far, FACT demonstrated that the stable and homogeneous performance of G-APDs allows for automatic and remote operation...
Mr
Bernhard Siebenborn
(Karlsruhe Institute of Technology (KIT))
03/06/2014, 10:00
The EURECA direct dark matter search experiment, as outlined in its Conceptual Design Report (http://www.sciencedirect.com/science/article/pii/S2212686414000090#), will consist of up to 1 ton of cryogenic (T~15mK) detector mass. The detectors will be Ge-Bolometers of EDELWEISS type and CaWO4 detectors of CRESST type. Each individual detector with a mass of ~1kg brings 4 to 6 channels which...