Description
The upgrade of the Low Level Radio Frequency (LLRF) system at the
superconducting linear accelerator ELBE is about to being finished. A
digital system based on MTCA.4 has been implemented and is going to
replace the analogue system which is in operation since 20 years by the
end of 2018. The digital system is capable for continuous wave (CW)
operation and single cavity control.
The server application uses the open source project ChimeraTK and its
OPC-UA adapter, that is based on the open source project open62541. This
allows to integrate the digital LLRF into the existing ELBE control and
machine protection system, that is based on a Siemens PLC (S7)
infrastructure. Furthermore, the OPC-UA adapter of ChimeraTK allows to
implement different additional clients of the ChimeraTK server
application, such as the ELBE human machine interface used by the
operators (WinCC, SCADA) or expert panels (e.g. LabView or Python).
The talk summarizes first results of the full integration test including
LLRF controller optimization and amplitude and phase noise
measurements. Furthermore, latest developments of the OPC-UA adapter and
contributions to ChimeraTK are presented.
Primary author
Klaus Zenker
(HZDR)