Simulation and Analysis TF

Europe/Berlin
Description

Topic: LUXE simulation and analysis TF
Meeting ID: 916 7025 7822
Password: 434044
Time: This is a recurring meeting Meet anytime

Join from PC, Mac, Linux, iOS or Android: https://weizmann.zoom.us/j/91670257822?pwd=L01uZHJMTmtmNkdpUklOTnlMU1M5QT09


Or Telephone:
    Dial(for higher quality, dial a number based on your current location): 
        US: +1 206 337 9723  or +1 470 250 9358 
        United Kingdom: +44 131 460 1196  or +44 203 481 5237 
        Israel: +972 3 978 6688 
    Meeting ID: 916 7025 7822
    Password: 434044
    International numbers available: https://weizmann.zoom.us/u/aQxpHqFgj

Or an H.323/SIP room system:
    H.323: 
        162.255.37.11 (US West)
        162.255.36.11 (US East)
        115.114.131.7 (India Mumbai)
        115.114.115.7 (India Hyderabad)
        213.19.144.110 (Amsterdam Netherlands)
        213.244.140.110 (Germany)
        103.122.166.55 (Australia)
        149.137.40.110 (Singapore)
        64.211.144.160 (Brazil)
        69.174.57.160 (Canada)
        207.226.132.110 (Japan)
    Meeting ID: 916 7025 7822
    Password: 434044

    SIP: 91670257822@zoomcrc.com
    Password: 434044

Or Skype for Business (Lync):
    https://weizmann.zoom.us/skype/91670257822

 

Intro:

 

Daniel:

- went to 900 nm wavelength —> a bit smaller energy of the Comptons

- electrons emittance is the dominant contribution to the uncertainty

- 1 ps pulse duration? —> this is OK.

- need to know what is the optimal spot size 

- slide 16: transverse momentum doesn’t look too small and it will affect the reco of e+e- pairs? —> will need to see this with the pairs coming from the main IP.

- don’t we have Comptons which produce pairs in the ICS IP? —> no, xi is too small.

- Beate:

  - focusing to different sizes at the ICS IP can be done but the magnets have to be strong enough but ~5-20 um seems OK. —> need a talk from the machine person (focusing options…)

  - where do we actually do the focusing of the electron beam? —>  ~20 m upstream the LUXE setup.

- Sasha:

  - in the case of the target there’s also multiple scattering so there’s no clear correlation between the focusing and the number of pairs. (on the question where do focus the beam - the main IP or the ICS IP?)

  - Sasha has the function which generates the electrons with correlated position and momentum —> please share.

 

 

Tom:

- I’d wait with large scale submissions (more BXs etc) except for what’s needed for the CDR fixes

 

Arka: 

- add the relative difference in angle before and after the window

There are minutes attached to this event. Show them.