Measurements of the transverse emittance for 200 pC bunch charge at the ELBE SRF Gun

26 Jun 2025, 10:29
3m
Seminar Room 1-3 (DESY)

Seminar Room 1-3

DESY

Platanenallee 6, 15738 Zeuthen
Poster (including Speed Talk) Beam diagnostics Beam Diagnostics

Speaker

Raffael Niemczyk (Helmholtz-Zentrum Dresden-Rossendorf)

Description

Radio-frequency (RF) guns are essential components of accelerator-based light sources. The superconducting continuous-wave RF (SRF) gun at ELBE, operated by Helmholtz-Zentrum Dresden-Rossendorf (HZDR), can drive multiple beamlines, including the THz beamline TELBE. TELBE is typically operated with a 200 pC bunch charge beam. The transverse emittance of the resulting beam is measured using a single-slit scan in a drift section following the gun. This poster presents the emittance measurement setup used at ELBE and shows results for the projected emittance measurements at a 200 pC bunch charge.

Primary authors

Raffael Niemczyk (Helmholtz-Zentrum Dresden-Rossendorf) André Arnold (HZDR) Gowrishankar Thalagavadi Hallilingaiah Dr Ulf Lehnert (Helmholtz-Center Dresden-Rossendorf) Shuai Ma (Helmholtz-Zentrum Dresden Rossendorf) Anton Ryzhov (Helmoltz-Zentrum Dresden-Rossendorf) Louis Stein Jochen Teichert (HZDR) Rong Xiang (HZDR)