Simulation and Analysis TF

Europe/Berlin
Description

Topic: LUXE simulation and analysis TF
Meeting ID: 916 7025 7822
Password: 434044
Time: This is a recurring meeting Meet anytime

Join from PC, Mac, Linux, iOS or Android: https://weizmann.zoom.us/j/91670257822?pwd=L01uZHJMTmtmNkdpUklOTnlMU1M5QT09


Or Telephone:
    Dial(for higher quality, dial a number based on your current location): 
        US: +1 206 337 9723  or +1 470 250 9358 
        United Kingdom: +44 131 460 1196  or +44 203 481 5237 
        Israel: +972 3 978 6688 
    Meeting ID: 916 7025 7822
    Password: 434044
    International numbers available: https://weizmann.zoom.us/u/aQxpHqFgj

Or an H.323/SIP room system:
    H.323: 
        162.255.37.11 (US West)
        162.255.36.11 (US East)
        115.114.131.7 (India Mumbai)
        115.114.115.7 (India Hyderabad)
        213.19.144.110 (Amsterdam Netherlands)
        213.244.140.110 (Germany)
        103.122.166.55 (Australia)
        149.137.40.110 (Singapore)
        64.211.144.160 (Brazil)
        69.174.57.160 (Canada)
        207.226.132.110 (Japan)
    Meeting ID: 916 7025 7822
    Password: 434044

    SIP: 91670257822@zoomcrc.com
    Password: 434044

Or Skype for Business (Lync):
    https://weizmann.zoom.us/skype/91670257822

Tom:
- can start from Bremss? —> yes
- HDF5 - how can it be read? —> h5py… c++,… can be also converted to root.
- resources: how much do we need? (this is also missing from the CDR)
- need to decide what configurations to generate —> will prioritise later
- what is the size of HDF5? 1M macro-electrons —> 50Gb (need to verify)

Sasha:
- how slow is the simulation? —> not too slow
- how many macro particle are going to the dump? —> probably too few
- can we do full sim bkg-only? —> start at least 1 BX per setup.
- neutrons probably not generating signal in the silicon particularly but will damage the sensors

Maryna1:
- procedure from the Hits tree: Edep in the cell divided by the mass of the cell
- how to account the damage from neutrons —> no Edep…? 
- the stats is ~10 times lower with the new simulation so the numbers between the tables are a bit different 

Maryna2:
- remove CKV from the fwd area? —> add to task list 
- remove pipe+Kapton option
- need a vacuum chamber after the magnet
- profiler1 can be the target
- profiler2 should be after the detector

Arka:
- Sasha to update the B-field values in the online table
- Need engineering eye on the upstream shielding 
- Need to enlarge the pipe before the IP chamber 

There are minutes attached to this event. Show them.