- Indico style
- Indico style - inline minutes
- Indico style - numbered
- Indico style - numbered + minutes
- Indico Weeks View
Topic: LUXE simulation and analysis TF
Meeting ID: 916 7025 7822
Password: 434044
Time: This is a recurring meeting Meet anytime
Join from PC, Mac, Linux, iOS or Android: https://weizmann.zoom.us/j/91670257822?pwd=L01uZHJMTmtmNkdpUklOTnlMU1M5QT09
Or Telephone:
Dial(for higher quality, dial a number based on your current location):
US: +1 206 337 9723 or +1 470 250 9358
United Kingdom: +44 131 460 1196 or +44 203 481 5237
Israel: +972 3 978 6688
Meeting ID: 916 7025 7822
Password: 434044
International numbers available: https://weizmann.zoom.us/u/aQxpHqFgj
Or an H.323/SIP room system:
H.323:
162.255.37.11 (US West)
162.255.36.11 (US East)
115.114.131.7 (India Mumbai)
115.114.115.7 (India Hyderabad)
213.19.144.110 (Amsterdam Netherlands)
213.244.140.110 (Germany)
103.122.166.55 (Australia)
149.137.40.110 (Singapore)
64.211.144.160 (Brazil)
69.174.57.160 (Canada)
207.226.132.110 (Japan)
Meeting ID: 916 7025 7822
Password: 434044
SIP: 91670257822@zoomcrc.com
Password: 434044
Or Skype for Business (Lync):
https://weizmann.zoom.us/skype/91670257822
Intro (CKV+screen):
- will check without internal shielding
- take the window a bit above the bottom of the straws (a few cm’s) and add shielding below to cover also the fibres etc.
- prefer to have the support all the way to the beam pipe without the vertical part close to the beam
- extend also the screen to 1m
- think about clamps
Stuart:
- redesign of the beam transport to get a better focus IP
- we can get ~5 um in principle but we should plan for something between 5 to 10 um
- larger beam is easier
- 7.5 um is achievable and the 5 um should also be achievable (TBC)
- for now we go with 5 um for the 1st prod. and Stuart will confirm in a few weeks if we need to assume something larger
Noam (window):
- change to 300 um
- check the window height when the 1st round of the signal after G4 simulation - 24 mm may be too large
- measure also the deformation over long time under max vacuum
Tom:
- need some feedback from Matt and Gianluca (min/max w0)
- how many BXs to simulate? —> for now 10 is fine
- maybe use 10^5 macro-particles and more BXs?
John:
- what material is implemented for the straws? —> will talk with Louis
- take cad from Oz (later today)
Maryna:
- why not increase the depth of the insert from 10 cm to e.g. 30 cm?
- don’t need an insert from the back of the wall
Sasha:
- small change in the dump (a centric hole ~10 cm deep and 3 cm wide)
- need some feedback from Marco et al for the profiler
- BSM detector should be circular or rectangular with short axis being >1m
- the b-field is of a C-shape magnet —> probably needs to be symmetrized for a proper dipole