Speaker
Matthias Hoffmann
(MSK (Strahlkontrollen))
Description
Using a novel RF receiver technique based on a carrier-suppression interferometer (CSI), we have achieved sub-femtosecond RF field control stability on a 1.3GHz CW superconducting RF (SRF) cavity at the Cryo-Module Test Bench (CMTB) at DESY. The CSI provides an improved RF sensitivity of a factor 100 and is used in addition to the standard RF down-converter. The CSI signal is added as an amplified error signal to the feedback controller. Performance evaluation is done by an out-of-loop CSI, which is capable to measure the stability of the cavity field relative to the RF reference from the main oscillator.
Primary author
Matthias Hoffmann
(MSK (Strahlkontrollen))
Co-authors
Andrea Bellandi
(None)
Bartlomiej Szczepanski
(MSK (Strahlkontrollen))
Christian Schmidt
(MSK (Strahlkontrollen))
Frank Ludwig
(MSK (Strahlkontrollen))
Mr
Heinrich Pryschelski
(MSK)
Klaus Zenker
(Helmholtz-Zentrum Dresden-Rossendorf)
Louise Springer
(DESY (Deutsches Elektronensynchrotron))
Michael Kuntzsch
(HZDR)
Uros Mavric
(MSK (Strahlkontrollen))