25–27 Jun 2025
DESY
Europe/Berlin timezone

Sub-fs SRF cavity control at CMTB

26 Jun 2025, 14:20
20m
Seminar Room 1-3 (DESY)

Seminar Room 1-3

DESY

Platanenallee 6, 15738 Zeuthen

Speaker

Matthias Hoffmann (MSK (Strahlkontrollen))

Description

Using a novel RF receiver technique based on a carrier-suppression interferometer (CSI), we have achieved sub-femtosecond RF field control stability on a 1.3GHz CW superconducting RF (SRF) cavity at the Cryo-Module Test Bench (CMTB) at DESY. The CSI provides an improved RF sensitivity of a factor 100 and is used in addition to the standard RF down-converter. The CSI signal is added as an amplified error signal to the feedback controller. Performance evaluation is done by an out-of-loop CSI, which is capable to measure the stability of the cavity field relative to the RF reference from the main oscillator.

Primary author

Matthias Hoffmann (MSK (Strahlkontrollen))

Co-authors

Andrea Bellandi (None) Bartlomiej Szczepanski (MSK (Strahlkontrollen)) Christian Schmidt (MSK (Strahlkontrollen)) Frank Ludwig (MSK (Strahlkontrollen)) Mr Heinrich Pryschelski (MSK) Klaus Zenker (Helmholtz-Zentrum Dresden-Rossendorf) Louise Springer (DESY (Deutsches Elektronensynchrotron)) Michael Kuntzsch (HZDR) Uros Mavric (MSK (Strahlkontrollen))

Presentation materials