Simulation and Analysis TF

Europe/Berlin
Description

Topic: LUXE simulation and analysis TF
Meeting ID: 916 7025 7822
Password: 434044
Time: This is a recurring meeting Meet anytime

Join from PC, Mac, Linux, iOS or Android: https://weizmann.zoom.us/j/91670257822?pwd=L01uZHJMTmtmNkdpUklOTnlMU1M5QT09


Or Telephone:
    Dial(for higher quality, dial a number based on your current location): 
        US: +1 206 337 9723  or +1 470 250 9358 
        United Kingdom: +44 131 460 1196  or +44 203 481 5237 
        Israel: +972 3 978 6688 
    Meeting ID: 916 7025 7822
    Password: 434044
    International numbers available: https://weizmann.zoom.us/u/aQxpHqFgj

Or an H.323/SIP room system:
    H.323: 
        162.255.37.11 (US West)
        162.255.36.11 (US East)
        115.114.131.7 (India Mumbai)
        115.114.115.7 (India Hyderabad)
        213.19.144.110 (Amsterdam Netherlands)
        213.244.140.110 (Germany)
        103.122.166.55 (Australia)
        149.137.40.110 (Singapore)
        64.211.144.160 (Brazil)
        69.174.57.160 (Canada)
        207.226.132.110 (Japan)
    Meeting ID: 916 7025 7822
    Password: 434044

    SIP: 91670257822@zoomcrc.com
    Password: 434044

Or Skype for Business (Lync):
    https://weizmann.zoom.us/skype/91670257822

Intro:
- need to have a radiation map for the racks etc

Louis:
- can go in air
- too much energy is dumped outside of the dump.
- dump is not encompassed in shielding so we will have leakage
- should have a long rectangular dump
- probably not limited by weight we can put on the floor

Vacuum/Hybrid:
- can have tiered vacuum with membranes?
- can access without breaking the vacuum of the machine (can be done with valves)
- get-valve upstream
- can the vacuum (1e-6 Pa) be kept with the 200 um Kapton and also if the chamber doesn’t collapse
- check 0.5mm also 2mm aluminium in terms of bkg.
- preference to go in vacuum and optimise the window in terms of bkg.
- reduce the joint between the triangular part and the beampipe.
- can we replace the aluminium/Kapton by diamond (radiation length is smaller)?
- check also how much the Kapton can take in terms of radiation —> low melting point
- AWAKE was 2mm of aluminium —> preferred there.
- we go w/o vacuum where the Cherenkov and the screen are pushed backwards (e+laser #2hybrid)

Ruth:
- can do the measurement with “e+laser #2hybrid”
  - this still depends on the magnet
  - this is linked to the length of the dump
- do not want to put the CKV in vacuum (access and gas tightness)

John:
- better energy resolution for “e+laser #2hybrid”
- need ~20 cm between the CKV and the screen so the camera has a line of sight
- solution of the vacuum with a transparent window / have the camera inside the vacuum chamber —> this is doable but not good.
- need to design much better the screen supports etc since it is going to generate bkg (Oz? —> Sasha)

Marco:
- not desirable (complicated, expensive)
- can perfectly work outside the vacuum